DuoLuX® Chemiluminescent and Fluorescent Substrate, Peroxidase (HRP) (SK-6604-200)

The product has been discontinued

Please contact Technical Support @ [email protected] for assistance in finding alternative.

Description

The DuoLuX Chemiluminescent/Chemifluorescent Substrate can be used for western, Southern, northern, or dot blots, or for ELISA applications. This substrate is about 10 times more sensitive than the alkaline phosphatase substrate BCIP/NBT and about 100 times more sensitive than the peroxidase substrate DAB. In addition to its chemiluminescent properties, the reaction product of the DuoLuX Substrate is also fluorescent.

Features:

  • Unique formula based on acridan chemistry
  • Very high sensitivity
  • Prolonged and intense light emission
  • Permanent fluorescence
  • Luminescence – peak emission at 453 nm
  • Fluorescence – excitation maximum at 405 nm (also excites at 254 nm and 365 nm). Maximum fluorescence emission at 453nm.

Specifications

Unit Size200 ml
ApplicationsBlotting Applications, Elispot, ELISAs
Detection Enzyme(s)Peroxidase
Substrate Reaction ProductChemiluminescent/ Chemifluorescent Product

What’s in the box:

  • 100 ml DuoLuX Substrate (Reagent 1)
  • 100 ml Peroxidase Converter Solution (Reagent 2)

Citations

Technical Information

Contents:

The DuoLuX Chemiluminescent/Chemifluorescent Substrate for peroxidase (SK-6604) is supplied in two bottles, consisting of 100 ml of the DuoLuX Substrate (Reagent 1) and 100 ml of a peroxidase converter solution (Reagent 2). Reagents 1 and 2 are mixed in equal volumes just prior to use, providing 200 ml of peroxidase substrate working solution.

Chemiluminescent properties

Light emission of the DuoLuX Chemiluminescent/ Chemifluorescent Substrate occurs continuously over a long period of time for both the peroxidase and alkaline phosphatase substrates. With either substrate formula, reacted DuoLuX Substrate luminesces in the blue range with a peak emission at 453 nm. Unlike other chemiluminescent substrates, blots can be reexposed to film many times over an 8 hour period to optimize band intensities or resolution.

Dlchemilumlifetime400 Jpg Dlchemilumlifetime400 Vectorlabs

Serial dilutions (1:2) of mouse IgG were resolved by PAGE, transferred onto nitrocellulose membrane and detected with the DuoLuX™ Substrate using either the Alkaline Phosphatase-based VECTASTAIN® ABC-AmP Kit (lower left) or Peroxidase Streptavidin (lower right). Graph shows prolonged light emission characteristics of the DuoLuX™ Substrate with each enzyme.

Fluorescent Properties

In addition to its chemiluminescent properties, the reaction product of the DuoLuX Substrate is also fluorescent. Fluorescence can be recorded with a digital imaging system or a conventional camera months after chemiluminescence has faded. The excitation maximum is at 405 nm, but other wavelengths (254 nm and 365 nm) also excite. Maximum fluorescent emission occurs at 453 nm. For fluorescence detection, nitrocellulose is recommended due to the intrinsic fluorescence of nylon. Acquisition of fluorescent signal requires a much shorter exposure time than chemiluminescence, often a fraction of a second.

Dlfluor400 Jpg Dlfluor400 Vectorlabs

Western blot visualized by fluorescence using the VECTASTAIN® ABC-AmP Kit with the DuoLuX™ Substrate. Serial dilutions (1:2) of rabbit IgG heavy chain were resolved by PAGE, transferred onto nitrocellulose membrane, and detected with biotinylated anti-rabbit IgG, followed by the VECTASTAIN® ABC-AmP Kit with the DuoLuX™Substrate. [A] Fluorescent detection by image acquisition (1 second). [B] Fluorescent image of the same blot as shown in [A] obtained 12 months later. (Same 1 second acquisition time.)

Applications

The DuoLuX Chemiluminescent/Chemifluorescent Substrate is ideal for development of protein and nucleic acid blots.  Complete kits are available for western blot development (VECTASTAIN® ABC-AmP system).

Protein Detection

For western For western blot applications using chemiluminescent detection, the sensitivity using either alkaline phosphatase or peroxidase is approximately 1 pg of protein. Film exposure times using peroxidase are generally 5-30 seconds; exposure times for alkaline phosphatase are 1-5 minutes. Using fluorescence detection, sensitivities are less than 10 pg of protein. For western blots, DuoLuX™ Chemiluminescent/Chemifluorescent Substrate can be used on either nitrocellulose or PVDF membranes but, in general, nitrocellulose is preferred.

Dlwestchemi400 Jpg Dlwestchemi400 Vectorlabs

Western blot visualized by chemiluminescence. Serial dilutions of rabbit IgG heavy chain were resolved by electrophoresis, transferred onto nitrocellulose membrane and detected with biotinylated anti-rabbit IgG, using the VECTASTAIN® ABC-AmP Kit with the DuoLuX™ Substrate. Chemiluminescent detection was captured by exposure to film.

Dlwestfluor400 Jpg Dlwestfluor400 Vectorlabs

Western blot visualized by fluorescence. Serial dilutions (1:2) of mouse IgG were resolved by PAGE, transferred onto nitrocellulose membrane, and detected with biotinylated anti-mouse IgG, Peroxidase Streptavidin and the DuoLuX™ Substrate. Fluorescent image was obtained in 0.07 seconds.

Nucleic acid detection

For developing Southern, northern, or dot blots using alkaline phosphatase, typical film exposure times range from 30 seconds to 10 minutes with sensitivity ranging from 100 fg to 10 pg of nucleic acid. Using peroxidase, exposure times are somewhat shorter and sensitivities are slightly less than those for alkaline phosphatase. Both nitrocellulose or nylon membranes can be used.

Dlsouthernchemi400 Jpg Dlsouthernchemi400 Vectorlabs

Southern blot of the E. coli phosphoenolpyruvate carboxylase gene.  Various dilutions of a 1.3 kb PCR product of the E. coli ppc gene was labeled with PHOTOPROBE® (LA) Biotin and hybridized to immobilized Tsp509 I-digested E. coli genomic DNA.  Probe was detected with Alkaline Phophatase Streptavidin followed by DuoLuX™ Substrate visualized by chemiluminescence.

Applicable patents and legal notices are available at legal notices.