Vector Laboratories is closed for the President’s Day on Monday, February 19th. We will be back in the office on Tuesday, February 20th.
We will respond to emails upon our return. Have a wonderful day.

ImmPRESS®-AP Goat Anti-Rat IgG Polymer Detection Kit, Alkaline Phosphatase (MP-5404-15)

[text-backorder]

Description

The ImmPRESS polymerized reporter enzyme staining system uses novel conjugation and micropolymer chemistries to create a highly sensitive, ready-to-use, one-step, biotin-free detection system. This unique micropolymer of highly active enzyme (alkaline phosphatase) is attached to our affinity purified secondary antibodies, producing reagents with outstanding sensitivity and low background.  

Features:

  • Enhanced accessibility to nuclear and membrane antigens
  • Ready-to-use in a convenient dropper bottle
  • Shorter assay time
  • Simplified multiple labeling

 

The ImmPRESS (15 ml) Kit will stain approximately 75-150 sections.

Specifications

Unit Size15 ml
ApplicationsImmunohistochemistry / Immunocytochemistry, In situ hybridization, ELISAs
TechnologyMicropolymer Reagents
Detection Enzyme(s)Alkaline Phosphatase
ConjugateMicropolymer AP
Target SpeciesRat
FormatReady-to-Use

Kit Contents:

  • 15 ml ImmPRESS-AP (alkaline phosphatase) Polymer Anti-Rat IgG Reagent (ready-to-use)
  • 15 ml 2.5% Normal Goat Serum for blocking (ready-to-use)

Product FAQs

The ImmPRESS Excel kits are a two-step peroxidase polymer based detection system that include an unconjugated amplifier antibody. This intermediate amplifier antibody increases sensitivity of the assay at least three- to four-fold over that of a one-step polymer based system, by facilitating the introduction of more peroxidase enzyme at the site of specific antigen localization. This increase in sensitivity would be advantageous in instances of weak antigen expression, and to further dilute out an expensive primary antibody. The ImmPRESS Excel Amplifier kits are presented as a complete kit format that include enzyme quench, blocking serum and ImmPACT® DAB EqV peroxidase substrate, in addition to the amplifier antibody and defined ImmPRESS polymer secondary antibody. However, as the two published references below indicate, this format is still modular and allows for the substitution of different detection reagents. These references describe using ImmPACT NovaRED™ peroxidase substrate in combination with the ImmPRESS Excel Amplifier kits. Oncogenesis (2017) 6, e293; doi:10.1038/oncsis.2016.82 Tan, E.M.S., et al (2017) Front. Med. 4:162 (doi: 10.3389/fmed.2017.00162)

Yes, we conducted studies on the compatibility of the ImmPRESS HRP polymer reagents with three commercially available autostainers (Agilent/Dako Autostainer Plus, Leica Bond Rx, and Ventana Discovery Ultra). We showed that our reagents are suitable for IHC detection on each of these platforms. The ImmPRESS polymer reagents and enzyme substrates generated equivalent IHC staining results compared to reagents from the instrument manufacturer. Some modifications in the protocol were performed to optimize the signal-to-noise ratio, such as a shorter incubation time for the ImmPRESS polymer and increase in the number of buffer washes following polymer incubation. Please see the following application note for more details about each automated platform:https://vectorlabs.com/wp-content/uploads/2022/11/VL_LIT3023_ImmPRESS_AppNote_4.pdf

Technical Information

The ImmPRESS-AP Alkaline Phosphatase Polymer Reagent micropolymer technology limits steric interference and provides enhanced accessibility to the target avoiding the disadvantages of other polymer systems that use large dextrans or other macromolecules as backbones.  The result is crisp, strong staining of antibody targets, especially nuclear and membrane antigens, and  greater sensitivity than conventional alkaline phosphatase antibody conjugates and other alkaline phosphatase polymer systems for immunohistochemistry and other applications. 
 

Immunostaining Protocol

The staining procedure is simple as shown in the diagram below. Following a blocking step with the diluted normal horse serum, sections are incubated with primary antibody. After a brief wash, the appropriate ImmPRESS Reagent is added to the sections and incubated for 30 minutes. Sections are again rinsed and the slides are developed with the peroxidase substrate of choice.

ImmPRESS SL600 jpg

 
Consider Species Cross-Reactivity

When choosing the optimal detection system for your application, it is important to consider not only the species of the primary antibody but also the species of the tissue. If the species of the primary antibody and the species of the tissue are closely related (e.g. rat and mouse), the secondary antibody may bind to endogenous IgG in the tissue section leading to background. The following options minimize background staining in these instances:

  • Use a secondary antibody specifically adsorbed to remove cross-reacting antibodies of closely-related species (e.g. ImmPRESS Anti-Mouse IgG, Rat Adsorbed).
  • Use the M.O.M.® ImmPRESS Kit (Cat. No. MP-2400) for applications of mouse primary antibodies on mouse tissue.

Applicable patents and legal notices are available at legal notices.

How do I Request a Quote?

To request a quote for products:

  1.  Log in to VectorLabs.com
  2.  Add the items you wish to quote to the cart;
  3.  View your cart;
  4.  Click on the “Request a Quote” button found below the items in your cart;
  5.  Download your quote