Skip to content

Click-&-Go® Cell Reaction Buffer Kit

Product No. 1263

Introduction

Click-&-Go® Protein Buffer Kit provides researchers everything required to perform the click reaction on cells tagged with an azide or alkyne and with the corresponding click detection reagent for subsequent downstream analysis by flow cytometry, fluorescence microscopy, or high content screening (HCS). Staining with additional detection reagents can performed prior or after the click reaction. Each kit includes sufficient material to perform 50 reactions based on 0.5 mL volume.

Kit Contents

ComponentConcent­rationAmo­untStor­ageStabi­lity
Reaction Buffer (Component A)10X4.0 mL2-8°CStable for at least 12 months when stored as directed.
Copper (II) Sulfate (Component B)100 mM600 μL
Reducing Agent (Component C)100 mg

Materials Required but Not Provided

Additional information

1262 scheme 01

Figure 1. Schematic representation of tagging of an azide-modified protein
with an alkyne-detection reagent via Cu(I)-catalyzed click reaction.

Material Preparation

Prepare Azide or Alkyne Detection ReagentPrepare detection reagent of choice in DMSO to a concentration of 2.5-5 mM. After use, store unused detection reagent stock at -20°C for up to 1 year.
Reaction Buffer (Component A)Prepare required amount of 1x Reaction Buffer by dilution 10 fold with deionized water. For example, to make 5 mL of 1x Reaction Buffer transfer 0.5 mL directly from 10x Reaction Buffer (Component A) into 4.5 mL of deionized water. Store unused 10x Reaction Buffer (Component A) for up to 6 months.
Copper (II) Sulfate (Component B)Ready to use. Stable for 1 year when stored at ambient temperature.
Reducing Agent (Component C)Dissolve Reducing Agent (Component C) in 4 mL of deionized water, vortex vigorously for 2 minutes or until pellet is completely dissolved. Store unused stock at -20°C. Stable for 1 year when stored as directed.
Note: reducing agent is susceptible to oxidation and turns brown when oxidized. If solution appears brown do not use.

Click Labeling Reaction

  1. Fix and permeabilize cells following a standard protocol.
  2. Wash cells once with 1-3% BSA in PBS.
  3. Prepare the reaction cocktail according to the table below.
  4. Add 0.5 mL reaction cocktail to each sample, mix well.
  5. Protect reaction from light and vortex continuously or rotate end-over-end for 25-30 minutes at room temperature.
  6. Wash cells once with 1–3% BSA in PBS.
  7. Stain with a desired counter stain or antibodies prior to imaging or flow analysis.
Note: the reaction cocktail should be used within 10 minutes of preparation.
Compo­nentNumber of Reactions
12510153050
1x Reaction Buffer (Compo­nent A)440 µL880 µL2.2 mL4.4 mL6.6 mL13.2 mL22 mL
Copper (II) Sulfate (Compo­nent B)10 µL20 µL50 µL100 µL150 µL300 µL500 µL
Reducing Agent (Compo­nent C)50 µL100 µL250 µL500 µL750 µL1.5 µL2.5 µL
Detec­tion Reagent1 to 5 μM final concentration, depending on the actual detection reagent used.
Total Volume500 µL1 mL2.5 mL5 mL7.5 mL15 mL25 mL


Download PDF file

Stay in the loop. Join Our Online Community.

The latest news, tips, and product releases delivered conveniently to your inbox.

We're Social Scientists! Let's connect.